Precise peristaltic pump BT100-2J

Precise peristaltic pump BT100-2J

Precise peristaltic pump BT100-2J could be loaded with YZ1515X, YZII15, YZ2515X, YZII25, DG-1/DG-2 and DG15-24/DG15-28. The pump provides flow rates from 0.0002mL/min to 380mL/min. The speed could be controlled through control panel, external control interface or RS485 interface. The running parameters are saved automatically. And the pump could be operated easily.

Flow rates:0.0002ml/min-380ml/min

Max. Number of Channels:2


Applications:

Suitable for laboratorial and industrial application



Product Instruction:

Precise peristaltic pump BT100-2J could be loaded with YZ1515X, YZII15, YZ2515X, YZII25, DG-1/DG-2 and DG15-24/DG15-28. The pump provides flow rates from 0.0002mL/min to 380mL/min. The speed could be controlled through control panel, external control interface or RS485 interface. The running parameters are saved automatically. And the pump could be operated easily.
CE certified product based on request.

Main Functions and Features

- Applicable pump heads: YZ1515X, YZ2515X, YZII15,YZII25, DG-1, DG-2
- Prime key for fast filling and emptying
- Adjust speed manually or automatically through analog interface.
- Memory function, storing the running parameters automatically
- Membrane keypad, easy to operate
- Good performance and low price
- Indoor use only.



Suitable Pump Head:


Suitable Tubing:


Flow Rate Curves:

Technical Specifications

- Speed: 0.1 to 100 rpm, reversible
- Speed precision: 0.1 rpm
- Speed control: Membrane keypad
- Display: 3-digit LED displays current rpm
- Communication interface: RS485
- External control: Start/stop, cw/ccw control  and speed control 0-5 V, 0-10 V, 4-20 mA and 0-10KHz
- Power supply: AC 90V-260 V 50/60 Hz
- Power consumption: ≤30 W
- Operating condition: Temperature 0 to 40 ℃
- Relative humidity < 80%
- Dimensions (L×W×H): 232×142×149 (mm)
- Drive weight: 2.3 kg
- IP rating: IP 31

Other parameters

Type Product
Code
Pump Head Tubing Max. Flow rate(ml/min) Weight
(kg)
BT100-2J 05.02.11A YZ1515x,YZII15 13# 14# 19# 16# 25# 17# 18# 380 2.7
YZ2515x,YZII25 15# 24# 270
DG-(1、2) 6 roller ID≤3.17mm
Wall Thickness 0.8-1mm
48 (single channel) 2.5-2.6
DG-(1、2) 10 roller 32 (single channel)
DG15-24 16# 25# 17# 300 (single channel) 3.1
DG15-28 13# 14# ID≤3.17mm
Wall thickness 0.8-1mm
75 (single channel) 3

Things to do after receiving a peristaltic pump

Longer Peristaltic Pump Operational Guide

2021-11-26

BT100-2J Acceptable Pump Heads and Tubing and Changing the pump head

Type Product Code Pump Head Tubing Max. Flow rate(ml/min) Weight (kg) BT100-2J 05.02.11A YZ1515x,YZII15 13# 14# 19# 16# 25# 17# 18# 380 2.7

2017-05-26

Precise peristaltic pump BT100-2J Basic Operation

Precise peristaltic pump BT100-2J could be loaded with YZ1515X, YZII15, YZ2515X, YZII25, DG-1/DG-2 and DG15-24/DG15-28. The pump provides flow rates from 0.0002mL/min to 380mL/min. The speed could be ...

2017-05-26

Precise peristaltic pump BT100-2J Introduction

Precise peristaltic pump BT100-2J could be loaded with YZ1515X, YZII15, YZ2515X, YZII25, DG-1/DG-2 and DG15-24/DG15-28. The pump provides flow rates from 0.0002mL/min to 380mL/min. The speed could be ...

2017-05-26

Fahrenheit/Celsius Temperature Conversion Table

Temperature Scales:The degree Fahrenheit (°F) is a unit of temperature named for the german physicist Gabriel Fahrenheit (1686 - 1736). In the Fahrenheit scale of temperature the freezing point of w...

2016-12-23

How to use External Control Function for BT100-2J

Communication Control Analog Control Show as below for external control module. If you need external control function you just insert the external control module to the external control interface whic...

2016-12-09

Tygon A-60-F Peristaltic Pump Tubing for LongerPump

ygon® A-60-F peristaltic pump tubing is ideal for use in clean-in-place and steam-in-place Peristaltic Pump BT100-2J, BT300-2J, BT100-1F, BT300-1F, etc. It is compatible with virtually all commercial...

2016-11-29

PharMed Tubing for Peristaltic Pump

PharMed Tubing for Peristaltic Pump

2016-04-20

Longer New/Old Model Corresponding Table

Longer New/Old Model Corresponding Table

2016-03-19

Longer Peristaltic Pumps Selection Sheet

Longer Peristaltic Pumps Selection Sheet (Model, Pump Head, Tubing, Flowrates)

2016-03-19

The Application of Longer Product in Liquid Filling Machines

The Liquid filling machine is a kind of packaging machine which fills packaging containers with a fixed quantity of liquid. The liquid filling machines can be classified into three types depending o...

2015-09-23

Laboratory Syringe Pump in Laboratories

A laboratory is a facility that provides controlled conditions for scientific or technological research, where experiments and measurements can be performed. Laboratories can be divided into 3 main ...

2015-09-11

The Application of Longer Product in the Pharmaceutical Industry

The pharmaceutical processes are mainly divided into chemically synthesized pharmaceuticals and biopharmaceuticals. The chemically synthesized pharmaceutical process produces drugs by chemical synthes...

2015-09-11