Dispensing & Filling System FB16-1 External Control Wiring
Release Time:2017-02-13
1 External Control Signal Control
Set the control mode as “external control”, refer to 3.2.1
Set user start signal as empty node.
External control signal cable definition:
Red wire: Start+
White wire: Start-
Blue wire: 485-B
Yellow wire: 485-A
2 No Bottle Signal Port
Connect no bottle signal wire between system and upper machine, control signal is empty node.
No bottle signal port definition as following:
1. Channel 1: no bottle + 2. Channel 2: no bottle +
3. Channel 3: no bottle + 4. Channel 4: no bottle +
5. No bottle enable 6. No bottle public
Set the control mode as “external control”, refer to 3.2.1
Set user start signal as empty node.
External control signal cable definition:
Red wire: Start+
White wire: Start-
Blue wire: 485-B
Yellow wire: 485-A
2 No Bottle Signal Port
Connect no bottle signal wire between system and upper machine, control signal is empty node.
No bottle signal port definition as following:
1. Channel 1: no bottle + 2. Channel 2: no bottle +
3. Channel 3: no bottle + 4. Channel 4: no bottle +
5. No bottle enable 6. No bottle public