Email:
 
Unit / Name:
 
Home> Products > Product by Series > Syringe Pump > Laboratorial Syringe Pump

Download the data needs of Member permissions,Please Login

New to Longer? Sign Up

LSP01-1A/2A Single Channel Syringe Pump

LSP01-1A/2A Single Channel Syringe Pump

LSP01-1A & LSP01-2A  laboratorial syringe pumps are single channel syringe pump which only has infusion mode. The acceptable syringe specification is from 10 μL to 60 mL. Suitable for high accuracy and small flow rate liquid transferring.

Flow rates:0.001μl-43.35ml/min

Max. Number of Channels:1


Applications:

For high precision fluid dosing, especially for laboratorial application.



Product Instruction:

LSP01-1A & LSP01-2A  laboratorial syringe pumps are single channel syringe pump which only has infusion mode. The acceptable syringe specification is from 10 μL to 60 mL. Suitable for high accuracy and small flow rate liquid transferring.
CE certified product based on request.

Main Functions and Features

- Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly
- Easy to operate: Combining big screen LCD display with rotary coded switch and membrane keypad makes the operation simple and prompt.
- Working Mode: Infusion
- Memory Function:
1. The parameters are saved in EEPROM. The parameters don't need to be reset when power returns after an interruption
2. In flow rate mode, the pump remains running or stop according to the setting parameters when power returns after an interruption
- Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked
- Communication Function: Realize computer control through RS485 communication interface
- External Control Function: Input/output control
- Calibration Function: Acquire accurate volume through calibration
- Syringe Protection: Adjust syringe rest to prevent syringe from damaging

Technical Specifications

Syringe pump LSP01-1A LSP01-2A
No. of Syringes 1 1
Advance per Mircostep 1/16step: 0.156 μm 1/16step: 0.031 μm
Infusion Volumn per Microstep 0.13 μL (60 mL BD Syringe) 0.026 μL (60 mL BD Syringe)
Syringe Size 10 μL - 60 mL 10 μL - 60 mL
Max. Linear Rate 65 mm/min 13 mm/min
Min. Linear Rate 5μm/min 1μm/min
Flow Rate 0.001μl/min -  43.349 ml/min 0.0002μL/min -  8.6699 ml/min
Working Mode Infusion
Linear Force > 9 kgf
Max. Step Rate 6933  (1/16step)/ sec
Min. Step Rate 16  (1/16 step) /30 sec
Accuracy ≤ 0.5% error in the condition of > 30% of max. infusion distance
Setting Mode Rotary coded switch and membrane keypad
Display 128 x 64 graphic LCD
Power AC 100 - 240 V
Operating Condition Temperature  5 °C - 40 °C       Relative humidity < 80 %
Dimensions 280 × 210 × 140 mm 280 × 210 × 140 mm
Weights 3.6 kg 3.6kg

Other parameters

Type Product Code Syringe Syringe ID (mm) Flow Rate (μl/min-ml/min)
LSP01-1A 0503401 10μl 0.50 0.001-0.0128
25μl 0.80 0.0025-0.0327
50μl 1.10 0.0048-0.0618
100μl 1.60 0.0101-0.1307
250μl 2.30 0.0208-0.2701
500μl 3.25 0.0415-0.5392
1ml 4.72 0.0875-1.1373
2ml 9.00 0.3181-4.1351
5ml 13.10 0.6739-8.7608
10ml 16.60 1.0821-14.068
20ml 19.00 1.4176-18.429
30ml 23.00 2.0774-27.006
60ml 29.14 3.3346-43.349

Type Product Code Syringe Syringe ID (mm) Flow Rate (μl/min-ml/min)
LSP01-2A 0503401 10μl 0.50 0.0002-0.0026
25μl 0.80 0.0005-0.0065
50μl 1.10 0.0095-0.0124
100μl 1.60 0.002-0.026
250μl 2.30 0.0042-0.054
500μl 3.25 0.0083-0.1078
1ml 4.72 0.0175-0.2275
2ml 9.00 0.0636-0.827
5ml 13.10 0.1348-1.7522
10ml 16.60 0.2164-2.8135
20ml 19.00 0.2835-3.6859
30ml 23.00 0.4155-5.4012
60ml 29.14 0.6669-8.6699

Laboratorial Syringe Pump LSP1-1A Keypad functions

Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly - Easy to operate: C...

2017-06-23

LSP01-1A/2A Single Channel Syringe Pump Operating Instructions

LSP01-1A & LSP01-2A laboratorial syringe pumps are single channel syringe pump which only has infusion mode. The acceptable syringe specification is from 10 μL to 60 mL. Suitable for high accuracy a...

2017-06-23

LSP01(04)-1A Syringe Pump Calibration

The flowrate can be calibrated for more accurate dispense volume.1.In parameters setting interface, press and turn RES to highlight the Calibration line. Press RES to enter calibration interface.

2017-01-06

LSP01(04)-1A Syringe Pump Power up

This option is only applicable when no dispense volume is selected. When power returns after an interruption the pump can resume operation (select Run) or remain stopped (select Stop).

2017-01-06

LSP01(04)-1A Single Channel Syringe Pump Flowrate setting

In parameters setting interface, turn and press RES to highlight the flowrate setting line. Press RES to make the numerical value position highlighted. Enter the flowrate required from the membrane ke...

2017-01-06

LSP01(04)-1A Single Channel Syringe Pump Volume setting

In parameters setting interface, turn and press RES to highlight the volume setting line. Press RES to make the numerical value position highlighted. Enter targeted volume from the membrane keypad. Pr...

2017-01-06

Syringe pump selection guides

A.How to select syringe? Choosing the proper specification according to the volume of dispensing fluid. B.How to select Dirve? Application dispensing mode of the fluid. Application environment and ins...

2015-12-19

Laboratory Syringe Pump in Laboratories

A laboratory is a facility that provides controlled conditions for scientific or technological research, where experiments and measurements can be performed. Laboratories can be divided into 3 main ...

2015-09-11

  • LSP01-1A 2A 3A&LSP04-1A Brochure Download

  • laboratorial syringe pump LVD CE Certificate Download

  • laboratorial syringe pump ECD CE Certificate Download