LSP01-1C Push & Pull Syringe Pump

LSP01-1C Push & Pull Syringe Pump

LSP01-1C is a push-pull simultaneous infusion/withdrawal pump. The acceptable syringe specification is from 10μL to 10mL. Suitable for high accuracy and small flow rate liquid continuously transferring.

Flow rates:0.831nl/min-10.84ml/min

Max. Number of Channels:1


Applications:

For high precision fluid dosing, especially for laboratorial application.



Product Instruction:

LSP01-1C is a push-pull simultaneous infusion/withdrawal pump. The acceptable syringe specification is from 10μL to 10mL. Suitable for high accuracy and small flow rate liquid continuously transferring.
CE certified product based on request.

Main Functions and Features

- Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly
- Easy to operate: Combining big screen LCD display with rotary encoder switch and membrane keypad makes the operation simple and prompt.
- Working Mode: Push-pull
- Memory Function: 1. The parameters are saved in EEPROM. The parameters don't need to be reset when power returns after an interruption. 2. In flow rate mode, the pump remains running or stops according to the setting parameters when power returns after an interruption
- Protection Function: The pump will stall and give an alarm when the drive structure of the pump is blocked
- Communication Function: Realize computer control through RS485 communication interface
- External Control Function: Input/output control
- Calibration Function: Acquire accurate volume through calibration
- Syringe Protection: Adjust syringe rest to prevent syringe from damaging


Technical Specifications

- Syringe size: 10μL-10mL
- Linear force: 9 Kg
- Advance per mircostep: 0.156 μm 1/16step
- Infusion volume per microstep: 0.026μL (10mL syringe 1/16 step)
- Max. step rate: 6933 1/16step /sec
- Min. step rate: 16 1/16step /30sec
- Max. linear rate: 65 mm/min
- Min. linear rate: 5μm/min
- Flow rates: 0.831 nL/min-10.84mL/min
- Accuracy: ≤0.5% error in the condition of
- Setting mode: Rotary coded switch and membrane keypad
- Display: 128×64 graphic LCD
- Power supply: AC100-240V
- Operating condition: Temperature 5℃-40℃, relative humidity <80%.
- Dimensions: 280×210×140(mm)
- Weight: 3.6 kg

Other parameters

Type Product Code Syringe Syringe ID (mm) Flow Rate (μl/min-ml/min)
LSP01-1C 0503421 10μl 0.50 0.001-0.0128
25μl 0.80 0.0025-0.0327
50μl 1.10 0.0048-0.0618
100μl 1.60 0.0101-0.1307
250μl 2.30 0.0208-0.2701
500μl 3.25 0.0415-0.5392
1ml 4.72 0.0875-1.1373
2ml 9.00 0.3181-4.1351
5ml 13.10 0.6739-8.7608
10ml 16.60 1.0821-14.068

LSP01-1C Syringe Pump External Control interface

External Control Function: Input/output control - Calibration Function: Acquire accurate volume through calibration - Syringe Protection: Adjust syringe rest to prevent syringe from damaging

2017-07-07

LSP01-1C Push & Pull Syringe Pump RS485 setup

Communication Function: Realize computer control through RS485 communication interface - External Control Function: Input/output control

2017-07-07

LSP01-1C Push & Pull Syringe Pump calibration

LSP01-1C is a push-pull simultaneous infusion/withdrawal pump. The acceptable syringe specification is from 10μL to 10mL.

2017-07-07

LSP01-1C Syringe setting

Syringe Selection: The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly

2017-07-07

LSP01-1C Push & Pull Syringe Pump Keypad functions

Syringe size: 10μL-10mL - Linear force: 9 Kg - Advance per mircostep: 0.156 μm 1/16step - Infusion volume per microstep: 0.026μL (10mL syringe 1/16 step) - Max. step rate: 6933 1/16step /sec

2017-07-07

LSP01-1C Push & Pull Syringe Pump Menu features

LSP01-1C is a push-pull simultaneous infusion/withdrawal pump. The acceptable syringe specification is from 10μL to 10mL. Suitable for high accuracy and small flow rate liquid continuously transferri...

2017-07-07

LSP01-1C Push & Pull Syringe Pump Operating Instructions

LSP01-1C is a push-pull simultaneous infusion/withdrawal pump. The acceptable syringe specification is from 10μL to 10mL. Suitable for high accuracy and small flow rate liquid continuously transferri...

2017-07-07

Laboratory Syringe Pump in Laboratories

A laboratory is a facility that provides controlled conditions for scientific or technological research, where experiments and measurements can be performed. Laboratories can be divided into 3 main ...

2015-09-11

  • Digital Lab Syringe Pump dLSP500 Quick to use guide Download

  • dLSP 500 UKCA Certificate--LVD Download

  • dLSP 500 UKCA Certificate--EMC Download

  • Digital Lab Syringe Pump Ben Nevis Download

  • laboratorial syringe pump LVD CE Certificate Download

  • laboratorial syringe pump ECD CE Certificate Download

  • LSP01-1C Push & Pull Syringe Pump Download