Email:
 
Unit / Name:
 
Home> Products > Product by Series > Syringe Pump > Laboratorial Syringe Pump

Download the data needs of Member permissions,Please Login

New to Longer? Sign Up

Programmable Syringe Pump TJP-3A

Programmable Syringe Pump TJP-3A

Controller and drive unit are separated.  With the programmable function, you can customize complex infusion/withdrawal process, such as stepped infusion, combination constant speed and ramped speed infusion, trigger dispense or periodic dispense.

Flow rates:0.138μl/min-52.94ml/min

Max. Number of Channels:1


Applications:

For high precision fluid dosing, especially for laboratorial application.



Product Instruction:

Controller and drive unit are separated.  With the programmable function, you can customize complex infusion/withdrawal process, such as stepped infusion, combination constant speed and ramped speed infusion, trigger dispense or periodic dispense.

Main Functions and Features

- User-defined syringe: Storing 4 inner diameters of user-defined syringe
- Linear force output: > 90 N
- Adopt membrane keypad, easy to operate
- Memory function: Storing the running parameters automatically
- Signal outputs: Start/Stop output, cw/ccw output (Open Collector)
- Calibration: Acquire accurate volume through calibration
- Fast forward & fast reverse: Infusion or withdrawal at the max. speed (158.8 mm/min)





Technical Specifications

- Max. Infusion Distance: 90 mm
- Acceptable Sample Syringe: 5 µL - 60 mL
- Linear Speed: 7.9 µm/min - 79.4 mm/min
- Adjusting Resolution: 7.9 µL/min
- Distance Resolution: 0.165 µm
- Linear Force: > 90 N
- Setting Mode: Membrane keypad and rotary coded switch
- Control Accuracy: < +/- 0.5% in condition of 30% of the full stroke
- Display: 128x64 graphic LCD
- External Control Interface: Start/Stop control, fast forward control, fast reverse control
- Communication Interface: RS485
- Power Supply: AC 100 V - 240 V or DC12V
- Power Consumption: < 10W
- Operating Condition: Temperature 0 to 40°C; relative humidity < 80%
- Controller Dimensions (Lx W x H) : 170 x 108 x 70 (mm)
- Controller Weight: 0.8 Kg
- Drive Unit Dimensions (L x W x H): 245 x 100x 95 (mm)
- Drive Unit Weight: 1.3 Kg

Other parameters

Contoller

(Product Code)

Driver Unit

(Product Code)

Syringe (ml)

Syringe ID

(mm)

Flow Rate

(μl/min-ml/min)

TJP-3A
(05.03.13A)
W0109-1B
(05.03.02A)
1 4.72 0.139-1.39
2 9.00 0.505-5.05
5 13.10 1.07-10.7
10 16.60 1.718-17.18
20 19.00 2.251-22.51
30 23.00 3.298-32.98
60 29.14 5.295-52.95

Syringe Pump TJP-3A Communication

Operator needs to set address and baud rate of controller when remotely controlling the pump by communication. The address range is from 1 to 30, there are three kinds of baud rates are optional, whic...

2017-09-08

Syringe Pump TJP-3A Running Parameters Setting

Different work mode is corresponding to different running parameters. Now divide five kinds of work modes into two categories: common mode and program mode. Common mode includes withdraw, infusion, in...

2017-09-08

Syringe Pump TJP-3A Work Mode Selection

There are five kinds of woke modes available, which are withdraw mode,infusion mode, infusion/withdraw mode, withdraw/infusion mode, program mode.

2017-09-08

Syringe Pump TJP-3A Setting & Selection of User-Define Syringe

In work mode and stop state, press RSC to enter to menu setting interface, turn RCS to highlight “Syringe”, press RCS to enter next interface. Turn RCS to highlight “User Define”, press RCS to ent...

2017-09-08

Syringe Pump TJP-3A Standard Syringe Selection

In work mode and stop mode, press RCS to enter menu setting interface, turn “RCS” to highlight “Syringe”, press RCS to enter next interface. Turn RCS to highlight “Manufacture”, press RCS to ent...

2017-09-08

Syringe Pump TJP-3A Language Selection

Switch on the controller, the controller will display product type, display language options interface after 1 second delay. Language selection interface will keep 3 seconds. Turn RCS to select necess...

2017-09-08

Syringe Pump TJP-3A Software Operation

Menu Navigation Vol : 2.000ml Flow: 12.00ml/m Time: 00:00:10 ■ → R0 C0 T2 Model: Infusion Syringe: 10ml Communication EXT.control: Infusion Withdraw I/W W/I Model:Infusion Communication EXT.control:...

2017-09-08

Programmable Syringe Pump TJP-3A Basic Function

Operation panel consists of membrane and LCD display, shown as below: 3. Usage & OperationLCD Screen Fast Forward/Stop Key Start/Pause Key Fast Reverse Key Exit Key Rotary Coded Switch (abbr. RCS, her...

2017-09-08

Programmable Syringe Pump TJP-3A System Installation

This chapter includes: Installing syringe Connection of data cable and power cord Follow below steps to install syringe:

2017-09-08

Programmable Syringe Pump TJP-3A System Structure

This syringe pump consists of TJP-3A controller and W0109-1B driveunit, shown as below。 Power Switch: Control the start/stop of syringe power supply.Power Socket: DC12V power supply input interface.

2017-09-08

Laboratory Syringe Pump in Laboratories

A laboratory is a facility that provides controlled conditions for scientific or technological research, where experiments and measurements can be performed. Laboratories can be divided into 3 main ...

2015-09-11

  • laboratorial syringe pump LVD CE Certificate Download

  • laboratorial syringe pump ECD CE Certificate Download

  • TJP-3A - Single Channel Syringe Pump Download