Terminal Definitionof Standard External Control Module
Release Time:2016-11-28
Terminal Definitionof Standard External Control Module
1#N/A
2#External start/stop control input. When connectedto COM,the pump runs; When connected to high level (5 - 12V), the pumpstops.
3#External cw/ccw control input. When connected toCOM, thepump rotates cw; When connected to high level (5- 12V), thepump stops.
4#Pulse speed control input, for external speedcontrol inexternal control module of 0 - 10 KHz.
5#Reference potential for external start/stop,cw/ccw and pulsespeed control input.