Mounting the MSP1-D1
09/28/2017
MSP1-D1 contains mounting holes in the top right and bottom left corners of the pump face. It is designed to mount to a panel using two M3 socket head cap screws. Shown as Figure 2-9
-
MSP1-D1 Industries Syringe Pump Installing Components
09/28/2017
See Chapter 5, "Maintenance," for the procedures for replacing and maintaining components. Below installing instruction is for the 3- ports valve
-
MSP1-D1 Printed Circuit Board Setting and Options
09/28/2017
DIP dial switch is used to configure different work modes, see Figure 2-4,shown DIP dial switch and status. Figure 2-4 DIP Dial Switch
-
MSP1-D1 Industries Syringe Pump Hardware Setup
09/28/2017
The MSP1-D1 requires a 24VDC power supply with a current rating of at least 500mA, provided through a DB-15 connector. LongerPump recommends using one power cable for every two pumps to provide noise ...
-
MSP1-D1 Industries Syringe Pump Functions
09/28/2017
MSP1-D1 uses a stepper-motor driven syringe and valve design to aspirate and dispense measured quantities of liquid. Both the syringe and the valve are replaceable. The illustrations below show the MS...
-
Syringe Pump TJP-3A Communication
09/08/2017
Operator needs to set address and baud rate of controller when remotely controlling the pump by communication. The address range is from 1 to 30, there are three kinds of baud rates are optional, whic...
-
Syringe Pump TJP-3A Running Parameters Setting
09/08/2017
Different work mode is corresponding to different running parameters. Now divide five kinds of work modes into two categories: common mode and program mode. Common mode includes withdraw, infusion, in...
-
Syringe Pump TJP-3A Work Mode Selection
09/08/2017
There are five kinds of woke modes available, which are withdraw mode,infusion mode, infusion/withdraw mode, withdraw/infusion mode, program mode.
-
Syringe Pump TJP-3A Setting & Selection of User-Define Syringe
09/08/2017
In work mode and stop state, press RSC to enter to menu setting interface, turn RCS to highlight “Syringe”, press RCS to enter next interface. Turn RCS to highlight “User Define”, press RCS to ent...
-
Syringe Pump TJP-3A Standard Syringe Selection
09/08/2017
In work mode and stop mode, press RCS to enter menu setting interface, turn “RCS” to highlight “Syringe”, press RCS to enter next interface. Turn RCS to highlight “Manufacture”, press RCS to ent...
-
Syringe Pump TJP-3A Language Selection
09/08/2017
Switch on the controller, the controller will display product type, display language options interface after 1 second delay. Language selection interface will keep 3 seconds. Turn RCS to select necess...
-
Syringe Pump TJP-3A Software Operation
09/08/2017
Menu Navigation Vol : 2.000ml Flow: 12.00ml/m Time: 00:00:10 ■ → R0 C0 T2 Model: Infusion Syringe: 10ml Communication EXT.control: Infusion Withdraw I/W W/I Model:Infusion Communication EXT.control:...