FK1-100Z External Control Interface Definition

Release Time:2017-02-13

Low level of control signal is valid.
1. Filling-stop without bottles signal for Channel 1;
2. Filling-stop without bottles signal for Channel 2;
3. Filling-stop without bottles signal for Channel 3;
4. Filling-stop without bottles signal for Channel 4;
5. Start/stop control signal;
6. Direction control signal (valid in stop mode);
7. COM (for 1 - 6 input signal)
8. On-line signal (Short 8 and 9 for On-line mode; Open 8 and
9 for Test mode);
9, 10: GND
11,12: B, A communication interface (Rs485)

Terminals definitions are as below. Terminal ranking 1 to 12 is from top to
bottom. Low level of control signal is valid.
1. Filling-stop without bottles signal for Channel 1;
2. Filling-stop without bottles signal for Channel 2;
3. Filling-stop without bottles signal for Channel 3;
4. Filling-stop without bottles signal for Channel 4;
5. Filling-stop without bottles signal for Channel 5;
6. Start/stop control signal;
7. Direction control signal;
8. COM (for 1 - 7 input signal)
9. On-line signal (Short 9 and 10 for On-line mode; Open 9 and 10 for Test
mode);
10: GND
11: RS485-B
12: RS485-A

On-line mode: Set on-line/test switch to on-line position, or short terminal 9
and 10 to enter on-line mode.
Test mode: Set on-line/test switch to test position, or open terminal 9 and 10 to enter test mode and set the parameters.