Disclaimer
Compact size and structure, utilizing a NEMA 23 stepper motor with an integrated driver.
Control the pump via the RS485 interface (supporting the Modbus RTU), or digital signals, analog signals, pulse signals.
| Parameters | T100&TH15 Series |
| Motor type | Stepper motor |
| Control circuit board | No |
| Max. flow rate (Single Channel) | 167mL/min |
| Pumphead model | TH15 |
| Pump speed | 0-100rpm |
| Control mode | The pump speed will be proportional to the external speed signal: 4-20mA |
| Control mode | The pump speed will be proportional to the external speed signal: 4-20mA |
| Control mode | The pump speed will be proportional to the external speed signal: 4-20mA |
| Control mode | The pump speed will be proportional to the external speed signal: 4-20mA |
| Control feature | No |
| Dimensions (L x W x H) | 85mmx85mmx134mm |
| Installation method | Panel Installation |
| Power supply | DC24V/10W |
| Operating temperature | 0℃-40℃ |
| Relative humidity | <80% |
Technical Specifications
T100-SE02-21&TH15-12-A | T100-SC02-21&TH15-12-A | |
Pump speed | 0-100rpm | |
Speed resolution | 0.1rpm | Modbus protocol: 0.01rpm Longer OEM protocol:0.1rpm |
Running direction control | Pump running direction is controlled by a switch signal (dry contact signal). The trigger mode can be configured via communication commands to either level trigger or pulse trigger. Factory default setting: level trigger mode, contact open for clockwise, contact closed for counterclockwise. | Communication control commands |
Start/stop control | Start/stop is controlled by a switch signal (dry contact signal). The trigger mode can be configured via communication commands to either level trigger or pulse trigger. Factory default setting: level trigger mode, contact open for start, contact closed for stop. | Communication control commands |
DIP switch setting for pump speed | The DIP switch can set the pump speed to 0-100rpm, and each DIP position corresponds to a step of 5rpm. | - |
External signals for pump speed | The pump speed will be proportional to the external speed signal: 4-20mA, 0-5V, 0-10V, 0-10kHz. The relationship between the signal range and speed range can be configured through communication commands. | Communication control commands |
Communication parameters | - | Baud rate:1200bps, 9600bps, 19200bps, 115200bps Parity:None or Even Pump address:1-32 Stop bit:1 bit |
Output | DC5V 100mA | |
Power supply | DC24V/10W | |
Dimensions(L*W*H) | 85mmx85mmx134mm | |
Mounting method | Panel mount | |
Working condition | Temperature: 0℃-40℃, relative humidity<80% | |
Weight | 0.9kg | |
Compatible Pump Head and Tubing
Pump Head | Tubing | Max Flow Rate(mL/min) |
TH15-12-A(included) | 13# | 7 |
14# | 22 | |
19# | 50 | |
16# | 80 | |
25# | 167 |
Dimensions

Product Enquiry
To purchase or learn more about our products, please contact us and our team will be happy to assist you.
Enquire NowDisclaimer
You are welcome to leave a message for consultation
Message